Online UPS Max - Series
Applications
Small computer network, servers, cyber cafe, banks and offices
Features
- High frequency and Double Conversion online technology
- High end Micro Controller based
- Wide Input voltage range
- Advanced PFC Technology
- Automatic battery Management
- Automatic battery charging in UPS off mode
- Short circuit and Overload Protection
- EMI/RFI Noise filter
- Smart RS232 Communication with monitoring software
- SNMP card slot (optional)
- LCD/LED Display simultaneously
- Specially Designed to suit Indian power and environment conditions
- Generator Compatible
- Isolation Transformer (optional)
|
IKVA ˜ 3KVA

 |
|
| Model |
MAX-SERIES |
036MX1KK11 |
096MX2KK11 |
096MX3KK11 |
| Capacity |
|
1KVA/700W |
2KVA/1400W |
3KVA/2100W |
| Input |
Voltage Range |
When load < 50%,range is 118±5VAC˜295±5VAC
when ≥50% load,input range is 160± 5VAC˜295±5VAC |
| Frequency |
46-54Hz+-0.5Hz |
| Phase |
Single Phase |
| Input Power Factor |
> 0.95 |
> 0.97 |
> 0.97 |
| Output |
Voltage Range |
220V˜2% |
| Frequency Range |
50Hz˜0.2% |
| THD(Linea Load) |
< 3% |
| THD(Non-Linea Load) |
< 5% |
| Overload Capability |
>110%,30sturn to bypass mode;
> 150%,200ms turn to bypass |
| Crest Factor |
3:1(max) |
| Short Circuit Protection |
5 cycles turn off inverter,no transfer to bypass,provide alarm(AC mode), 5 cycles turn off inverter,provide
alarm(battery mode),input fuse blown or breaker action |
| Waveform |
Pure Sine Wave |
| Transfer time AC to Bypass mode |
4ms (typical 2.5ms) |
| Efficiency |
85%˜92% |
85%˜92% |
85%˜92% |
| Battery |
DC Voltage |
36VDC |
96VDC |
96VDC |
| Charge Current |
0.5A˜10A |
0.5A˜10A |
0.5A˜10A |
| Communication Interface |
RS232; SNMP(optional) |
| LED/LCD Indication |
Load or battery Capacity |
| Noise Level |
<45db |
| Dimensions product(LxWxH)in mm |
412x144x213 |
470x191x338 |
470x191x338 |
 |
|
Online UPS SuperMax - Series - I
Applications
Networking equipments, computer rooms, mission critical process, banks, offices, railways, airport, hospitals, defense and telecom centers, all type of single Ph.Loads
Features
- True online Double Conversion technology
- High end Micro controller
- Automatic battery charging in UPS off mode
- Wide Input voltage range
- Short circuit and Overload Protection
- parallel Redundant / Hot Standby (optional)
- Galvanic Isolation
- 1 Phase in ~ 1 Phase out (up to 10KVA)
- 3 Phase in ~ 3 Phase out (up to 30KVA)
- Specially Designed to suit Indian power and environment conditions
- Generator Compatible
|
5KVA ˜ 30KVA

 |
|
| Model |
|
SUPERMAX-SERIES-I |
| Capacity |
|
5KVA to 30KVA |
| Technology |
|
Double Conversion High Freq.switching PWM,using IGBT's |
| Input |
Voltage Range |
160V AC ˜270V AC±5V AC,Single Phase for upto 10KVA and
360V AC˜450V AC±5V AC,Three Phase for upto 30KVA |
| Frequency |
45˜55Hz |
| Phase |
Single Phase upto 10KVA and Three Phase from 5 to 30KVA |
| Generator Compatibility |
Present |
| Output |
Voltage |
230V Ac ±1% |
| Frequency Range |
50Hz ± 0.5% |
| THD(Linea Load) |
< 3% |
| THD(Non-Linea Load) |
< 5% |
| Overload Capability |
>125% for 2minuted / 150% for 30 |
| Crest Factor |
3:1(max) |
| Short Circuit Protection |
Instant |
| Waveform |
Pure Sine Wave |
| Manual Bypass |
Inbuilt upto 15KVA |
| Static Bypass (optional) |
< 5ms |
| Inverter/Overall Efficiency |
85%˜92% |
| Battery |
DC Voltage |
180/ 360 VDC |
| Mimic Control Panel |
LED for UPS status and LCD for Voltage,Current & Frequency |
| Audible Alarm |
For Battery Low /DC High/Output High/Overload |
| Communication Interface |
RS232; SNMP(optional) |
| Optional |
Hot Stand By |
| Noise Level/ Cooling |
≤50dB / Forced Aircooled |
| Transient Response |
for 100% Step Load charge,±5% and recovers to normal within 20 miliseconds. |
| Ambient Temperature / Relative Humidity |
0-45º C/ 0-95% Non-Condensing |
|
|
Online UPS SuperMax - Series - II
Applications
software centers, mission critical process, offices, railways, airport, hospitals, defense, telecom centers, chemical plants, pharmaceutical and all types of three Ph. load eg. 3 ph. motor, lifts etc.
Features
- True online Double Conversion technology
- High end Micro controller / DSP based
- Automatic battery charging in UPS off mode
- Wide Input voltage range
- Advanced Battery Management
- Short circuit and Overload Protection
- Hot Standby (optional)
- Galvanic Isolation
- 3 Phase in ~ 3 Phase out
- Specially Designed to suit Indian power and
environment conditions
- Generator Compatible
|
|
5KVA ˜ 30KVA

|
| Model |
|
SUPERMAX-SERIES-II(3 Phase in ˜ 3 Phase out) |
| Capacity |
|
5KVA to 30KVA |
| Technology |
|
Double Conversion High Freq.switching PWM,using IGBT's |
| Input |
Voltage Range |
360V AC˜450V AC±5V AC,Three Phase |
| Frequency |
45˜55Hz |
| Phase |
Three Phase Three Wire (compatible for phase reversal) |
| Generator Compatibility |
Present |
| Output |
Voltage |
400V AC Phase to Phase ±3% on 100% unbalance load |
| Frequency Range |
50Hz ± 0.5% |
| Phase |
Three Phase Four Wire |
| THD(Linea Load) |
< 3% |
| THD(Non-Linea Load) |
< 5% |
| Overload Capability |
125% for 2minutes / 150% for 30Seconds |
| Crest Factor |
3:1(max) |
| Short Circuit Protection |
Instant |
| Waveform |
Pure Sine Wave |
| Static Bypass (optional) |
< 10ms |
| Inverter/Overall Efficiency |
85%˜92% |
| Battery |
DC Voltage |
360V DC |
| Mimic Control Panel |
LED for UPS status and LCD for Voltage,Current & Frequency |
| Audible Alarm |
For Battery Low /DC High/Output High/Overload |
| Communication Interface |
RS232; SNMP(optional) |
| Optional |
Hot Stand By |
| Noise Level/ Cooling |
≤50dB / Forced Aircooled |
| Transient Response |
for 100% Step Load charge,±5% and recovers to normal within 20 miliseconds. |
| Ambient Temperature / Relative Humidity |
0-45º C/ 0-95% Non-Condensing |
|
|